💬

Assistant Market Spas France

Market Spas France

Expert spa à votre service

Ignore and skip to content
Codes d'Erreur Spa : Guide par Écran Balboa & Gecko | Market Spas Codes d'Erreur Spa : Guide par Écran Balboa & Gecko | Market Spas

Spa Error Codes: Screen Guide for Balboa & Gecko | Market Spas

Codes d'Erreur Spa : Guide par Écran Balboa & Gecko | Market Spas

🖥️ Spa Error Codes: Screen Guide

Identify and quickly resolve errors displayed on your Market Spas control panel.

BALBOA

Balboa error codes

Balboa systems equip most Market Spas in the Performance and Premium collections.

📱

Balboa SpaTouch

Color touchscreen

🛁 Spas equipped with this screen

Volcano
Critical - Immediate action required
Warning - Monitor
Information - Normal
Code Meaning Solution
FLO Water flow problem Check water level, clean the filter, verify the circulation pump is working.
OH Overheat (>43°C) Remove the cover immediately. Let cool for 15-30 minutes.
HL High temperature limit High limit sensor triggered. Let cool and check circulation.
dr / dry Dry heater Not enough water for heating. Check water level and purge air from the pump.
SnA / SnB Temperature sensor failure Sensor A or B needs checking. Contact customer service if the error persists.
COOL Water too cold (<7°C) Normal in winter. Increase filtration time and target temperature.
ICE Frost protection activated The spa activates the pumps to prevent freezing. Check that the heater is working.
Pr Priming mode Normal after filling. Tap the pump icon to prime. Duration: 4-5 minutes.
--- Unknown temperature Water has not circulated through the sensors. Wait or activate a pump.

🔧 Quick troubleshooting SpaTouch

  • Navigation: Intuitive touch interface, swipe to access menus
  • General reset: Turn off the circuit breaker for 30 seconds, then turn it back on
  • Settings: Tap the ⚙️ icon to access advanced settings
  • Programs: Access filtration cycles and modes via the main menu
🖥️

Balboa TP600

Oval LCD screen • 6 buttons
📄 Download the guide

🛁 Spas equipped with this screen

Neptune V2 Mayotte
Critical - Immediate action required
Warning - Monitor
Information - Normal
Code Meaning Solution
FLO Water flow problem Check water level, clean the filter, verify the circulation pump is working. Open valves if closed.
OH Overheat (>43°C) Remove the cover immediately. Let cool for 15-30 minutes. If recurring, sensor or circulation failure.
dr / dry Dry heater Not enough water for heating. Check water level and purge air (airlock) from the pump.
SnA / SnB Temperature sensor failure Sensor A or B needs checking. Contact customer service if the error persists after a reset.
COOL Water too cold (<7°C) Normal in winter. Increase filtration time and target temperature.
ICE Frost protection activated The spa activates the pumps to prevent freezing. Check that the heater is working.
Pr / PrH Priming mode Normal after filling. Press "Jets" to prime the pumps. Duration: 4-5 minutes.
--- Unknown temperature Water has not circulated through the sensors. Wait or activate a pump.
HH / Hr Measured temperature too high Sensor failure or heater stuck on. Contact customer service.

🔧 Quick troubleshooting TP600

  • General reset: Turn off the circuit breaker for 30 seconds, then turn it back on
  • Clear an error: Press any button after resolving the issue
  • Check the mode: If "EC" or "SL" is displayed, switch to "ST" (Standard) mode for continuous heating
🖥️

Balboa TP700

Rectangular LCD screen • 7 buttons
📄 Download the guide

🛁 Spas equipped with this screen

Felicity Ecstatic Premium Collection (some models)
Code Meaning Solution
FLC Circulation fault Clogged filter or circulation pump failure. Clean the filter first.
OH Overheating detected Open the cover, let cool. Check water circulation.
HL High temperature limit High limit sensor triggered. Let cool and check sensors.
Sn1 / Sn2 / Sn3 Sensor 1, 2, or 3 error Temperature sensor failure. Identification and replacement by technician.
AoH Sensor A overheating Sensor A fault. Technical check needed.
PnL Panel communication error Check cable between panel and board. Reset recommended.
bUS Communication bus error Internal connection problem. Reset or technical service required.

🔧 Quick fix TP700

  • Menu navigation: Press "Mode" to access settings
  • Filtration: Press "Filter" + "Temp" simultaneously to program cycles
  • Factory reset: See the PDF guide for full procedure
🖥️

Balboa VL810D

Compact LCD screen • 8 buttons
📄 Download the guide

🛁 Spas equipped with this screen

Pleasure Soulmate Refresh Relax
Code Meaning Solution
FLO Insufficient flow Water level too low or dirty filter. Check and clean.
OHH Severe overheating Temperature above 44°C. Open the spa and let it cool down.
SnS Unbalanced sensors Difference between sensor A and B. Technical check recommended.
-- Temp not available Run the pump so water passes through the sensors.
SLP Sleep mode Normal. Press any button to exit standby mode.
🖥️

Balboa VL260

Simple LCD screen • 4 buttons
📄 Download the guide

🛁 Spas equipped with this screen

Tenerife Tenerife Midnight Santa Cruz Essential Collection
Code Meaning Solution
FL Flow problem Check filter and water level. Bleed air if necessary.
OH Overheat Remove cover, let cool for 20-30 minutes.
Sn Sensor error Temperature sensor failure. Contact customer service.
Pr Priming mode Press Jets to activate pumps. Normal at startup.
EC Economy mode Heats only during filtration. Switch to "ST" if needed.

🔧 Quick fix VL260

  • Change mode: Press "Mode" to switch between Standard (ST), Economy (EC), and Sleep (SL)
  • Set temperature: Press "Temp" then use the arrows
  • Parental lock: Hold "Temp" + "Light" for 3 seconds
GECKO

Gecko error codes

Gecko systems equip some spas from the Performance and Premium collections with advanced features.

📱

Gecko K1000 SmartTouch

Color touchscreen
📄 Download the guide

🛁 Spas equipped with this screen

Odin Eden Formentera Premium Collection (selection)
Code Meaning Solution
FLO Insufficient water flow Check water level, clean the filter, check the circulation pump.
HL High limit reached Overheating detected. Open the cover and let it cool down.
HFL Insufficient flow + overheating Circulation problem causing overheating. Check filter and pump urgently.
AmbS Faulty ambient sensor Ambient temperature sensor to check/replace.
WatS Faulty water sensor Water temperature sensor to check/replace.
P1H / P2H Pump error 1 or 2 Check the electrical connections of the affected pump.
OzE Ozonator error Ozonator fault. Can be disabled or replaced.
CFG Configuration mode Normal during first startup or after reset.
UPD Updating Do not interrupt. Wait until the process finishes.

🔧 Quick fix K1000

  • Navigation: Swipe the screen to access different menus
  • Settings access: Tap the gear icon ⚙️
  • Reset: Settings → System → Reset
  • Wifi: Some models allow control via the in.touch app
🖥️

Gecko K300 (in.K300)

LCD screen • 4 buttons
📄 Download the guide

🛁 Spas equipped with this screen

Serena Nova Mayotte Performance Collection
Code Meaning Solution
FLO Flow problem Water level, filter, or circulation pump. Check in this order.
HL Overheat Remove the cover and let the water cool naturally.
Sn Temperature sensor Faulty or disconnected sensor. Technical check needed.
P1 / P2 Pump error Pump 1 or 2 fault. Check power and connections.
--- Unknown temperature Activate a pump to circulate water through the sensors.

🔧 Quick fix K300

  • Menu access: Hold the center button for 3 seconds
  • Change mode: Press "Mode" for Standard/Economy/Sleep
  • Reset: Turn off the breaker for 30 seconds then turn it back on

💡 General Tips

🔄

The universal reset

Most errors can be fixed by cutting power at the breaker for 30 seconds, then turning it back on. This resets the system.

🔍

Check the simple things first

Before panicking: correct water level? Clean filter? Valves open? These 3 checks solve 80% of FLO errors.

🌡️

Overheat = circulation

OH/HL errors are almost always related to a circulation problem. Check the circulation pump and filter.

📸

Photograph the error

Before doing anything, take a photo of the screen. This will help customer service diagnose if the problem persists.

After filling

The "Pr", "---", and "FLO" errors are normal just after filling. Let the system prime for 5-10 minutes.

📱

View the PDF guide

Download the guide corresponding to your screen. It contains detailed diagrams and procedures for each error.

Unresolved error?

Our customer service team is available to help you diagnose and resolve your spa issues.

Back to top